MinnSpas | EZHotTubParts.com

Hot Tub Heater to Circuit Board Jumper Wire Set – 4-Inch

$12.99

HydroQuip 4-inch heater jumper wire set for connecting a compatible hot tub heater to the circuit board. Includes two 10-AWG jumper wires. An affordable add-on when replacing a heater, especially if the existing wires are scorched, brittle or corroded.

Compatible with many Balboa VS, EL and GS, Gecko, HydroQuip, Water Pro and SpaGuts systems. Not compatible with Balboa BP systems.

- +
⭐⭐⭐⭐⭐ 4.9/5 Google Rating
Guaranteed Safe Checkout

Hot Tub Heater to Circuit Board Jumper Wire Set – 4-Inch

This HydroQuip heater jumper wire set connects a compatible hot tub heater to the circuit board. The set includes two 4-inch, 10-AWG jumper wires.

Consider replacing the jumper wires when installing a new heater if the existing wires or terminals show heat damage, discoloration, corrosion, brittleness or loose connections. Reusing damaged wiring can cause excessive resistance, overheating and damage to the new heater or circuit board.

  • Includes two heater jumper wires
  • Connects the heater to the circuit board
  • Wire length: 4 inches
  • Wire size: 10 AWG
  • Useful add-on when replacing a compatible hot tub heater

Compatible Spa Control Systems

These heater jumper wires are compatible with many Balboa, Gecko, HydroQuip, Water Pro and SpaGuts heaters and circuit boards that use 4-inch heater-to-board wire connections.

Balboa recommends replacing the original copper heater straps with jumper wires on compatible VS, EL and GS control systems. Flexible wires can provide a better connection between the heater terminals and circuit board while reducing stress on the board.

Not compatible with Balboa BP control systems. Always compare the wire length, terminal connections and control-system configuration before ordering.

Hot tub electrical repairs should be completed with power disconnected. If the heater terminals or circuit-board connections are burned or damaged, have the complete system inspected by a qualified spa technician before installing new components.

Hot Tub Heater Jumper Wire FAQs

This product includes a pair of two 4-inch, 10-AWG jumper wires used to connect a compatible hot tub heater to the circuit board.

Replacement is recommended when the existing wires or terminals are scorched, discolored, corroded, brittle or loose. New jumper wires are inexpensive insurance against transferring a damaged connection to the new heater.

HydroQuip 48-0023 may also cross-reference with part numbers 30015, 30039, 30192, 30511, 9711-130, 9920-401161 and 2-05-0076. Always compare the wire length, gauge and terminal connections before ordering.

These 4-inch heater jumper wires are compatible with many Balboa, Gecko, HydroQuip, Water Pro and SpaGuts heaters and circuit boards. Balboa recommends replacing the original copper heater straps with wires on compatible VS, EL and GS systems. Always confirm the required wire length and terminal configuration before ordering.

No. These 4-inch heater-to-circuit-board jumper wires are not compatible with Balboa BP control systems.

Balboa recommends replacing the copper heater straps with wires on compatible VS, EL and GS systems. Flexible jumper wires reduce mechanical stress between the heater terminals and circuit board and are a good replacement when the original straps or connections are heat-damaged, loose or corroded.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

You may also like…

Shopping Cart
Scroll to Top